Accurex D-Dimer Fast Test Kit

₹ 18,500.00₹ 18,500.00

Intended for in vitro quantitative determination of D-Dimer in plasma or whole blood|Used as an aid in the assessment and evaluation of patients suspected of deep-vein thrombosis or pulmonary embolism|It has 25 tests

Quantity :

Category :Personal Care

Sub Category :Personal Care

Stock: Low in stock

Accurex D-Dimer Fast Test Kit uses an anti-human D-Dimer monoclonal antibody conjugated with fluorescence latex and another anti-human D-Dimer monoclonal antibody coated on the test line. After the sample has been applied to the test strip, the fluorescence latex-labelled anti-human D-Dimer monoclonal antibody binds with the D-Dimer in sample and forms a marked antigen-antibody complex. This complex moves to the test card detection zone by capillary action. Then marked antigen-antibody complex is captured on the test line by another anti-human D-Dimer monoclonal antibody. The fluorescence intensity of the test line increases in proportion to the amount of D-Dimer in sample. Then insert test card into Getein1100 Immunofluorescence Quantitative Analyzer (hereafter referred to as Getein1100), the concentration of D-Dimer in sample will be determined and displayed on the screen. The value will be stored in Getein1100 and available for downloading. The result can be easily transmitted to the laboratory or hospital information system.Uses:It is intended for in vitro quantitative determination of D-Dimer in plasma or whole blood. The test is used as an aid in the assessment and evaluation of patients suspected of deep-vein thrombosis or pulmonary embolism.Product Specifications and Features: It is intended for in vitro quantitative determination of D-Dimer in plasma or whole blood The test is used as an aid in the assessment and evaluation of patients suspected of deep-vein thrombosis or pulmonary embolism It has 25 tests Directions For Use: Collect specimen according to manual Test card, sample and reagent should be brought to roomtemperatureprior to testing Confirm SD card lot No. in accordance with test kit lot No. Perform?SDCard Calib? calibration when necessary On the main interface of Getein1100, press "ENT" button to enter testinginterface Remove the test card from the sealed pouch immediately beforeuse. Label the test card with patient or control identification Put the test card on a clean table, horizontally placed Using sample transfer pipette, deliver 100 ?l of sample into onetubeof sample diluent, mix gently and thoroughly. Then drop 100 ?l (or 3dropsof sample when using disposable pipet) of sample mixture into thesampleport on the test card After 10 minutes, insert the test card into Getein1100 and press "ENT" button The result will be shown on the screen Safety Information: For in vitro diagnostic use, only For professional use only Do not use the kit beyond the expiration date Do not use the test card if the foil pouch is damaged Do not open pouches until ready to perform the test Do not reuse the test card Do not reuse the pipet Handle all specimens as potentially infectious Proper handling anddisposal methods should be followed in accordance with local regulations Carefully read and follow the manual to ensure proper test performance

Add A Review

Your email address will not be published. Required fields are marked

Your Rating *

You need to Login OR Register

0 (Overall)

Based on 0 Comments